How to Clean TheraFace PRO Rings and Remove Conductive Gel

TheraFace PRO attachments do not all have the same washing permission. The device and its electronic treatment rings are wiped clean, while the detached Cleansing Ring is the running-water exception. After use, remove visible gel and skin-care residue with a damp cloth or alcohol-free cleansing wipe, then dry thoroughly. This guide covers cleaning the PRO device and its attachments, not the TheraFace Mask, treatment selection, or whether a particular therapy is appropriate for your skin.

Primary reference: Therabody official TheraFace PRO US user manual and care instructions. Always check the manual for your exact model.

Quick reference

Power
Off; charging cable disconnected
Body and electronic rings
Damp cloth or alcohol-free wipe
Running-water exception
Detached Cleansing Ring only
Before reuse
No visible debris or moisture
Exclude
Immersion, boiling, and dishwasher experiments

What you will need

  • Soft clean cloths
  • Clean water for lightly dampening a cloth
  • Alcohol-free cleansing wipes if preferred
  • A dry towel for detached attachments
  • The TheraFace PRO manual for your region

Step-by-step instructions

Step 1: Switch off and separate the attachments

Turn the device off and disconnect the charging cable. Work away from a filled sink and keep the cable on a dry surface. Remove the attachment ring by its intended magnetic connection, using the manual's illustrations if unfamiliar. Do not open the housing or pull apart an electronic ring. Lay each component where you can identify it: Cleansing Ring, microcurrent ring, LED ring, and any optional hot/cold rings require deliberate separation. A common magnetic connection does not mean a common immersion rating.

Step 2: Inspect the residue before adding moisture

Look for gel around the microcurrent contacts, cleanser around the Cleansing Ring, and cosmetic residue near attachment interfaces. Check for cracks, loose parts, or material that seems to have entered an opening. Routine cleaning is for accessible contamination; it is not a repair for fluid inside the device. Keep the light-producing surfaces protected from hard tools. If residue has dried, soften it with a controlled damp wipe instead of picking at it with a nail or blade.

Step 3: Wipe the device body gently

Use a damp soft cloth or an alcohol-free cleansing wipe, working around the grip and accessible outer surfaces. The cloth should not release drops when squeezed. Keep moisture out of the USB-C connector and other openings, and never hold the device under a running tap. Follow with a clean dry cloth as needed. Do not use facial exfoliating acids, household disinfectant sprays, or a skin toner as an equipment cleaner simply because those products are nearby on the bathroom counter.

Step 4: Remove gel from the electronic rings

Wipe accessible ring surfaces until gel and other visible residue are gone. Use a fresh section of cloth rather than spreading the same sticky film around the contact area. The US PRO manual specifies damp wiping or an alcohol-free cleansing wipe for the device and rings. Keep electronic attachments out of standing water. If the surface still feels coated after wiping, repeat gently rather than escalating to an alcohol soak.

Step 5: Rinse only the detached Cleansing Ring

Confirm that the component in your hand is the Cleansing Ring before using running water. Detach it first so the device cannot accidentally enter the stream. Rinse away cleanser and debris gently, paying attention to the textured cleaning surface, then shake off loose drops over the sink. Do not carry this exception over to the microcurrent, LED, or temperature-control attachments. A removable accessory can still contain electrical parts. No dishwasher or boiling cycle is part of this routine.

Step 6: Dry every contact area before reassembly

Place the cleaned pieces on a clean towel with airflow around them. Inspect recesses and magnetic contact areas for visible moisture. A dry-looking front surface is not enough if drops remain on the back of a ring. Let the device and attachments dry thoroughly before another treatment, storage, or charging. Do not use a hair dryer to force a quick turnaround. Keep a damp wipe or wet Cleansing Ring out of a closed case with the power cable.

Step 7: Reassemble and keep treatment decisions separate

Refit the dry attachment in its correct orientation without forcing it. If the ring does not seat normally, check for residue or a mismatch before powering on. Use the device's treatment instructions and precautions independently of this cleaning guide; clean equipment does not remove a therapy contraindication. If a contact error or irregular function persists, stop and consult Therabody. Record which ring is affected and whether the problem appeared before or after cleaning rather than repeatedly testing a possibly wet component.

Specific cleaning questions

Open a question for a concise answer about stains, odors, safety, frequency, and troubleshooting.

Can I rinse the whole TheraFace PRO under the tap?
No. The PRO manual identifies the detached Cleansing Ring as the running-water exception. The main device and electronic rings are wiped clean. Do not interpret water resistance or a facial-cleansing function as permission to wash the whole unit.
Can I use an alcohol wipe?
The cited PRO care instructions specify an alcohol-free cleansing wipe or a damp cloth. Follow those instructions rather than applying an alcohol routine from a different beauty device. A wipe must also be used without pushing liquid into openings.
How do I remove dried conductive gel?
Use a damp soft cloth and controlled repeated wiping on accessible surfaces. Allow the residue to soften rather than scraping it. Clean around the ring's contact area carefully, then dry the attachment fully before refitting it.
Is the microcurrent ring washable because it detaches?
No. Detachability makes it easier to wipe but does not establish a running-water or immersion permission. Keep it separate from the rinsable Cleansing Ring while cleaning so similar-looking attachment connections do not lead to a mix-up.
Can I boil or steam the Cleansing Ring?
The running-water exception is not authorization for boiling, steam sterilization, or a dishwasher. Use the cleaning method stated for the accessory. If you need a different decontamination method, ask Therabody about that exact component.
How often should I clean the device?
Make cleaning part of the after-use routine and inspect for gel or debris before the next session. The manual's endpoint is no visible debris or moisture. Do not store used attachments with a film of cleanser or conductive gel.
What if water entered the charging port?
Keep the device off and disconnected from charging. Do not insert tools or plug it in to see whether it still works. Seek manufacturer guidance for the suspected liquid exposure; ordinary surface cleaning does not resolve internal moisture.
Does a clean device mean I can use every treatment?
No. Cleaning and treatment suitability are different questions. Follow the current instructions and contraindications for the chosen attachment. This page explains equipment care and does not provide a skin-treatment plan or a medical clearance.